NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM177482 Query DataSets for GSM177482
Status Public on Oct 23, 2007
Title HV3-20-67CGH
Sample type genomic
 
Channel 1
Source name male DNA
Organism Homo sapiens
Characteristics male DNA
Extracted molecule genomic DNA
Extraction protocol DNA was isolated using the QiAmp DNA isolation kit (Qiagen, Hilden, Germany) and subsequently quantified by a fluorometric assay (Quant-iT Pico Green dsDNA Kit, Invitrogen, Karlsruhe, Germany). Fluorescence was measured using a TECAN (Salzburg, Austria) SpectrafluorPLUS microplate fluorescence reader with an excitation wavelength at 485 nm and an emission wavelength at 535 nm. DNA concentrations were calculated from a standard curve of double-stranded control DNA provided with the kit that was measured in triplicate at the concentrations 30, 3, 0.3, and 0.03 ng/µl (measured by fluorometry).A volume of 2.5 µl out of 4 ng/µl dilutions from cell lines and control DNA was used as starting material for the amplification. The phi29-amplification was carried out according to the Repli-G kit manufacturer's instructions (Qiagen) using an incubation time of 16 h. Repli-G reactions were checked by a real time based intra Alu-PCR assay. Additionally DNA concentration was fluorimetrically measured with Quant-iT Pico Green dsDNA Kit (Invitrogen) and ranged between 10-30 Ž¼g.
Label cy3
Label protocol 10 µg of amplified and purified DNA were labeled using the BioPrime Array CGH Genomic Labeling kit (Invitrogen) according to the manufacturer¢â¬â„¢s instructions in a volume of 50 µl with a modified dNTP mix containing 120 µM each of dATP, dGTP, and dCTP; 60 µM dTTP; and 60 µM Cy5-dUTP or Cy3-dUTP. Labeled DNA was purified using QIAquick PCR purification columns (Qiagen). Tumor and reference DNA were pooled, mixed with 50 µg Cot-1 DNA (Invitrogen) and concentrated to a volume of 20 µl in a vacuum centrifuge. DNA was then mixed with an equal amount of 2x formamide buffer, denaturated at 95°C for 5 min and preincubated at 37°C for 30 min in a waterbath.
 
Channel 2
Source name LNCaP-CN4 2
Organism Homo sapiens
Characteristics male DNA
Extracted molecule genomic DNA
Extraction protocol DNA was isolated using the QiAmp DNA isolation kit (Qiagen, Hilden, Germany) and subsequently quantified by a fluorometric assay (Quant-iT Pico Green dsDNA Kit, Invitrogen, Karlsruhe, Germany). Fluorescence was measured using a TECAN (Salzburg, Austria) SpectrafluorPLUS microplate fluorescence reader with an excitation wavelength at 485 nm and an emission wavelength at 535 nm. DNA concentrations were calculated from a standard curve of double-stranded control DNA provided with the kit that was measured in triplicate at the concentrations 30, 3, 0.3, and 0.03 ng/µl (measured by fluorometry).A volume of 2.5 µl out of 4 ng/µl dilutions from cell lines and control DNA was used as starting material for the amplification. The phi29-amplification was carried out according to the Repli-G kit manufacturer's instructions (Qiagen) using an incubation time of 16 h. Repli-G reactions were checked by a real time based intra Alu-PCR assay. Additionally DNA concentration was fluorimetrically measured with Quant-iT Pico Green dsDNA Kit (Invitrogen) and ranged between 10-30 Ž¼g.
Label cy5
Label protocol 10 µg of amplified and purified DNA were labeled using the BioPrime Array CGH Genomic Labeling kit (Invitrogen) according to the manufacturer¢â¬â„¢s instructions in a volume of 50 µl with a modified dNTP mix containing 120 µM each of dATP, dGTP, and dCTP; 60 µM dTTP; and 60 µM Cy5-dUTP or Cy3-dUTP. Labeled DNA was purified using QIAquick PCR purification columns (Qiagen). Tumor and reference DNA were pooled, mixed with 50 µg Cot-1 DNA (Invitrogen) and concentrated to a volume of 20 µl in a vacuum centrifuge. DNA was then mixed with an equal amount of 2x formamide buffer, denaturated at 95°C for 5 min and preincubated at 37°C for 30 min in a waterbath.
 
 
Hybridization protocol DNA samples were hybridized onto the array for 16-18 hours at 42°C utilizing the MAUI 4-bay hybridization system and MAUI Mixer A0 (BioMicro System, Salt Lake City, UT, USA). After hybridization arrays and MAUI Mixer were disassembled in 42°C 1xSSC and 0.05% SDS (wash solution 1) and subsequently washed two times in wash solution 1 for 5 minutes followed by two washes in 0.1xSSC (wash solution 2) for 5 minutes.
Scan protocol Dried array slides were scanned using a ScanLite Express microarray scanner (Perkin Elmer, Wellesley, MA, USA). Raw image files of the arrays were processed using DeArray software (Chen et al, 1997) and resulting image data were imported into R environment using bioconductor packages (Gentleman RC et al., 2004) for further analysis.
Description male DNA
Data processing Loess normalization
 
Submission date Mar 27, 2007
Last update date Mar 13, 2008
Contact name Sean Davis
E-mail(s) sdavis2@mail.nih.gov
Phone 301-435-2652
Organization name National Cancer Institute
Lab Genetics Branch
Street address 37 Convent Drive, Room 6138
City Bethesda
State/province MD
ZIP/Postal code 20892
Country USA
 
Platform ID GPL5046
Series (1)
GSE7376 Detection of novel amplification units in prostate cancer

Data table header descriptions
ID_REF
VALUE log2 ratio (sample/reference)

Data table
ID_REF VALUE
24 0.310292068293827
12 0.0722451320807752
120 1.13374630848833
108 0.0173598595671156
216 0.33240002843391
204 -0.0819180655807557
312 0.403838337452539
300 -0.140887921270476
408 -0.0548522756867726
396 -0.140210362132201
504 0.149502311007421
492 0.187074768793101
600 0.445759848739819
588 1.44953054258739
696 -0.00425283009058075
684 0.0125243421159942
792 -1.22336505919129
780 -0.0224535878872420
888 -0.0671847191805419
876 -0.525012143015088

Total number of rows: 36288

Table truncated, full table size 817 Kbytes.




Supplementary file Size Download File type/resource
GSM177482_Result.txt.gz 2.7 Mb (ftp)(http) TXT

| NLM | NIH | GEO Help | Disclaimer | Accessibility |