NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM546210 Query DataSets for GSM546210
Status Public on Feb 08, 2011
Title Feces, Infected, 1
Sample type other
 
Source name Feces, infected
Organism Mus musculus
Characteristics strain: C57BL/6
gender: female
tissue: feces
infection: Salmonella enterica serovar Typhimurium SL1344
molecule type: metabolites
Treatment protocol Oral infection with 7.5x10^7 Salmonella enterica serovar Typhimurium SL1344.
Growth protocol Not applicable.
Extracted molecule other
Extraction protocol To extract metabolites from livers and feces, acetonitrile was added to samples (approximately 1 μL of acetonitrile per 1 μg of tissue), which were then homogenized. The samples were then cleared by centrifugation and the supernatant was collected into a new tube and dried at room temperature using a centrifuge equipped with a vacuum pump. All extracts were kept at -80oC until further use.
Label Not applicable
Label protocol Not applicable.
 
Hybridization protocol Not applicable.
Scan protocol Not applicable.
Description F-I-1
Each sample was measured twice.
Data processing Raw mass spectrometry data were processed using a custom-developed software package, as described elsewhere (Han et al. 2008. Metabolomics. 4:128-140 [PMID 19081807]). First, raw mass spectra acquired from each sample group were batch-processed using the instrument vendor’s data analysis software, DataAnalysis®, but with a home-written VBA script to do automatic internal mass calibration with the reference masses of the spiked calibration standards and a known contaminant, N-butylbenzensulfonamide. Monoisotopic peaks corresponding to the isotopic pattern distributions were then automatically determined and those with a signal/noise ratio above 3 were picked. Their m/z values were converted to neutral masses by subtracting 1.007276 for positive ion mode or adding 1.007276 for negative ion mode. Next, the resulting mass lists from all the mass spectra within each set of uninfected/infected groups detected in positive or negative ion modes were further processed with another customized software program developed with LabVIEW® (National Instruments, Austin, USA). The first step of this software is to remove the adduct ions (M+Na)+ and (M+K)+ in positive ion mode and (M+Cl)- in negative ion mode from the mass lists based on the expected mass differences for these ions within 2 ppm to yield a list of unique biochemical component masses together with their peak intensities. The peak intensities of all the monoisotopic neutral masses are subsequently normalized to the intra-sample total ion intensity. Masses observed in at least three of four samples (feces) or two of three samples (livers) of one of the conditions (infected or uninfected) were aligned and combined into unique metabolite features from the masses that matched within 2 ppm across all the data. Finally, a two-dimensional data matrix (mass vs. relative intensity) was generated for each sample group and saved in a format amenable for further data analysis. To identify differences in metabolite composition between samples from uninfected and infected mice, we first filtered our list of masses for metabolites which were present in one set of samples (uninfected or infected) but not the other. Additionally, we averaged the mass intensities of metabolites in each group and calculated the ratios between averaged intensities of metabolites from uninfected and infected mice. To assign possible metabolite identities to the masses present in only one of the sample groups or showing at least a 2-fold change in intensities between the sample groups, the monoisotopic neutral masses of interest were queried against MassTrix (http://masstrix.org), a software designed to incorporate mass queries into metabolic pathways. Masses were searched against the Mus musculus database within a mass error of 3 ppm.
 
Submission date May 21, 2010
Last update date Feb 09, 2011
Contact name L. Caetano M. Antunes
E-mail(s) antunes@mail.ubc.ca
Phone 604-827-3921
Organization name The University of British Columbia
Department Michael Smith Laboratories
Lab Finlay Lab
Street address #367 - 2185 East Mall
City Vancouver
State/province BC
ZIP/Postal code V6T 1Z4
Country Canada
 
Platform ID GPL10454
Series (1)
GSE21720 A metabolomics analysis of Salmonella infection

Supplementary file Size Download File type/resource
GSM546210_F-I-1_a_neg.baf.gz 3.2 Mb (ftp)(http) BAF
GSM546210_F-I-1_a_pos.baf.gz 3.2 Mb (ftp)(http) BAF
GSM546210_F-I-1_b_neg.baf.gz 3.2 Mb (ftp)(http) BAF
GSM546210_F-I-1_b_pos.baf.gz 3.2 Mb (ftp)(http) BAF
Processed data are available on Series record

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap