Coronary angiography-derived contrast fractional flow reserve

Catheter Cardiovasc Interv. 2022 Feb;99(3):763-771. doi: 10.1002/ccd.29558. Epub 2021 Feb 15.

Abstract

Background: Based on coronary angiography and mean aortic pressure, a specially designed computational flow dynamics (CFD) method is proposed to determine contrast fractional flow reserve (cFFR) without using invasive pressure wire. This substudy assessed diagnostic performance of coronary angiography-derived cFFR in catheterization laboratory, based on a previous multicenter trial for online assessment of coronary angiography-derived FFR (caFFR).

Methods: Patients with diagnosis of stable angina pectoris or unstable angina pectoris were enrolled in six centers. Wire-based FFR was measured in coronary arteries with 30-90% diameter stenosis. Offline angiography-derived cFFR was computed in blinded fashion against the wire-based FFR and caFFR at an independent core laboratory.

Results: A total of 330 patients were enrolled to fulfill inclusion/exclusion criteria from June 26 to December 18, 2018. Offline angiography-derived cFFR and wire-based FFR results were compared in 328 interrogated vessels. The statistical analysis showed the highest diagnostic accuracy of 89.0 and 86.6% for angiography-derived cFFR with a cutoff value of 0.94 and 0.93 against the wire-based FFR with a cutoff value of 0.80 and 0.75, respectively. The corresponding sensitivity and specificity were 92.2 and 87.3% for the cutoff value of 0.94 and 80.0 and 88.4% for the cutoff value of 0.93, which are similar to those against the caFFR. The receiver-operating curve has area under the curve of 0.951 and 0.972 for the wire-based FFR with the cutoff value of 0.80 and 0.75, respectively.

Conclusions: Coronary angiography-derived cFFR showed higher accuracy, sensitivity, and specificity against wired-based FFR and caFFR. Hence, angiography-derived cFFR could enhance the hemodynamic assessment of coronary lesions.

Keywords: computational flow dynamics; contrast; fractional flow reserve; instantaneous wave-free ratio.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coronary Angiography / methods
  • Coronary Artery Disease* / diagnostic imaging
  • Coronary Stenosis* / diagnostic imaging
  • Coronary Vessels / diagnostic imaging
  • Fractional Flow Reserve, Myocardial*
  • Humans
  • Predictive Value of Tests
  • Severity of Illness Index
  • Treatment Outcome