Computer analysis of fixation-suppression of caloric nystagmus

ORL J Otorhinolaryngol Relat Spec. 1982 Sep-Oct;44(5):277-87. doi: 10.1159/000275604.

Abstract

Effects of the ocular fixation upon caloric nystagmus were quantitatively analyzed and compared between normal subjects and patients by using a PDP 11/40 computer. The slow-phase velocity was the best parameter to separate normal from abnormal visual fixation. An analysis of caloric nystagmus with failure of fixation-suppression (FFS) made it possible to classify patterns of FFS into three types. The combination of FFS with impairment of the optokinetic responses provides a useful diagnostic tool with respect to lesions located between the brain stem and the cerebellum.

MeSH terms

  • Adult
  • Brain Neoplasms / diagnosis
  • Brain Stem / physiopathology
  • Caloric Tests*
  • Cerebellum / physiopathology
  • Cerebrovascular Disorders / diagnosis*
  • Computers
  • Electronystagmography
  • Female
  • Fixation, Ocular*
  • Humans
  • Male
  • Middle Aged
  • Vestibular Function Tests*