NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Series GSE49756 Query DataSets for GSE49756
Status Public on Mar 17, 2014
Title A Transcriptomic Reporter Assay Employing Neutrophils to Measure Immunogenic Activity of Septic Patients' Plasma (Expt. 2)
Organism Homo sapiens
Experiment type Expression profiling by array
Summary The wide array of molecules carried by plasma regulates critical immune functions and constitutes valuable biomarkers and therapeutic targets. In recent years the introduction of “systems approaches” has provided investigators with powerful means for assessing immune responses in patient samples on a global scale. However, while the use of genome-wide profiling technologies has become widespread, measuring the plasma proteome still presents considerable challenges. An alternative approach that consists in measuring transcriptome responses in reporter cells exposed in vitro to patient plasma has been successfully employed in a limited number of studies. Here we devised such a “Transcriptomic Reporter Assay” system to assess the immunogenicity of plasma from septic patients and evaluate its potential for biomarker discovery. Sepsis is a common, severe systemic infectious process for which physicians still lack efficient diagnostic or prognostic tools. Of the three different cell reporter systems tested, neutrophils were identified as the most capable “plasma sensor”. Compared to peripheral blood mononuclear cells and dendritic cell preparations neutrophils were best able to discriminate between plasma from septic and control subjects and responded by upregulating a robust immune transcriptional program. Additionally, the amplitude of the neutrophil transcriptomic response was shown to be associated with disease severity in two additional sets of patients. Overall, our results demonstrate both the suitability and potential clinical relevance of a neutrophil reporter assay for assessing immunopathogenic processes in a complex and severe condition such as sepsis.
 
Overall design Polymorphonuclear neutrophils (PMNs) were isolated a healthy donor. Plasma samples were obtained from a first set of patients with culture-confirmed sepsis (n=29) and from uninfected controls (n=17). PMNs were cultured for 6 h in medium alone, plasma from patients with sepsis, plasma from uninfected controls, and LPS using a final concentration of 20%. Transcriptional profiles were acquired using Illumina HumanHT12 V4 BeadChips.
 
Contributor(s) Khaenam P, Rinchai D, Chiche L, Altman MC, Buddhisa S, Kewcharoenwong C, Suwannasaen D, Mason M, Whalen E, Susaengrat W, O’Brien K, Nguyen Q, Gersuk V, Linsley P, Lertmemongkolchai G, Chaussabel D
Citation(s) 24612859
Submission date Aug 10, 2013
Last update date Aug 13, 2018
Contact name Damien Chaussabel
E-mail(s) DChaussabel@benaroyaresearch.org
Organization name Baylor Institute for Immunology Research
Street address 3434 Live Oak
City Dallas
State/province TX
ZIP/Postal code 75204
Country USA
 
Platforms (1)
GPL10558 Illumina HumanHT-12 V4.0 expression beadchip
Samples (49)
GSM1206538 H3-LPS1
GSM1206539 H3-Med1
GSM1206540 H3-Med2
This SubSeries is part of SuperSeries:
GSE49758 A Transcriptomic Reporter Assay Employing Neutrophils to Measure Immunogenic Activity of Septic Patients' Plasma
Relations
BioProject PRJNA214843

Download family Format
SOFT formatted family file(s) SOFTHelp
MINiML formatted family file(s) MINiMLHelp
Series Matrix File(s) TXTHelp

Supplementary file Size Download File type/resource
GSE49756_RAW.tar 26.2 Mb (http)(custom) TAR
GSE49756_non-normalized.txt.gz 15.1 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap