NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM2522803 Query DataSets for GSM2522803
Status Public on Oct 16, 2017
Title SEP3-AGe2-R1
Sample type SRA
 
Source name synthetic Oligos
Organism synthetic construct
Characteristics chip antibody: Custom made, peptide specific antibody, anti-AG (Eurogentec), HPLC-purified
round of selex enrichment: 1
Extracted molecule other
Extraction protocol The dsDNA libraries were made from the ssDNA sequences by single-cycle PCR amplification with a complementary primer essentially as described before (Jolma et al., 2010). The dsDNA libraries contained 20 random nucleotide fragment flanked by specific barcodes that allowed for later characterization when multiplexed in high-throughput sequencing. Protein dimers were synthesized using TNT SP6 Quick Coupled Transcription/Translation System (Promega) following the manufacturer’s instructions in a total volume of 20 µl and equimolar expression plasmid concentrations. The binding reaction mix was prepared essentially as described previously for EMSA experiments (Egea-Cortines et al., 1999; Smaczniak et al., 2012b) and contained 20 µl of in vitro-synthesized proteins and 50-100 ng of dsDNA library in a total volume of 120 µl. The binding reaction was incubated on ice for 1 h followed by 1 h immunoprecipitation with protein specific antibodies (affinity-purified peptide antibodies, Eurogentec) coupled to magnetic beads (MyOne, Invitrogen) in a thermomixer at 4 °C with constant mixing at 700 rpm. Magnetic beads with attached antibodies where prepared in advance according to manufacturer’s instructions (MyOne, Invitrogen) with purified antibodies resuspended in 1X PBS (~1 mg/ml); 20 µg of antibodies and 0.5 mg of beads were used for a single binding reaction. After immunopreciptiation, beads were washed 5 times with 150 µl of binding buffer without salmon-sperm DNA and bound DNA was eluted with 50 µl 1X TE in a thermomixer at 90 °C with full mixing speed. Afterwards, magnetic beads were immobilized and the supernatant was transferred to a 1.5-ml tube. DNA fragments were amplified with 10 to 15 cycles of PCR with SELEX round-specific primers (Jolma et al., 2010) and the total amplicon was used in the subsequent SELEX round. The amplification efficiency was checked on the agarose gel by comparing to a known concentration of a standard probe. Samples for sequencing, after amplification, were cut out from agarose gel and purified using MinElute Gel Extraction Kit (Qiagen).
Each SELEX library was quantified by Qubit and processed by BioAnalyser. The same rounds of SELEX were multiplexed by mixing in equimolar amounts and diluted to 10 nM. Such multiplexed libraries were processed following Illumina's "Denature and Dilute Libraries Guide" with 40% PhiX control. Samples were sequences on GAII or HiSeq2000.
 
Library strategy SELEX
Library source genomic
Library selection other
Instrument model Illumina HiSeq 2000
 
Data processing Basecalls performed using CASAVA version 1.8
Read that did not pass the filter quality of CASAVA 1.8 were removed
Reads that mapped to the PhiX174 genome allowing one misatche were removed (using Soapv2 )
Barcodes at the beginning and at the end of the sequence read were used (no mistmach allowed) to obtain the different libraries provided. Barcoded were eliminated from the sequence read
Genome_build: Not applicable- SELEX reads are not aligned to reference genome
Supplementary_files_format_and_content: Relative affinities were calculated for all possible 12-mer sequence. Tables providing information of sequence of the 12-mer, relative affinity, and standard deviation of the relative affinity estimation are included in the submission
 
Submission date Mar 06, 2017
Last update date May 15, 2019
Contact name Jose M. Muino
E-mail(s) jose.muino@hu-berlin.de
Organization name Humboldt University
Department Department of Biology
Street address Rhoda-⁠Erdmann-⁠Haus (Haus 22); R 1216 Philippstr. 11-⁠13;
City Berlin
ZIP/Postal code 10115
Country Germany
 
Platform ID GPL15228
Series (1)
GSE95730 Differences in DNA-binding specificity of floral homeotic protein complexes predict organ-specific target genes
Relations
BioSample SAMN06481568
SRA SRX2614244

Supplementary data files not provided
SRA Run SelectorHelp
Raw data are available in SRA
Processed data are available on Series record

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap