NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM746951 Query DataSets for GSM746951
Status Public on Jun 23, 2011
Title MIX_1-4_CON-5
Sample type RNA
 
Source name MIX 1-4 exposure, control treatment, 24h, replicate 5
Organism Daphnia magna
Characteristics tissue: whole organism
sample type: control
Treatment protocol Acetone was used as solvent carrier. Exposures were done with moderately hard-reconstituted water. An equivalent volume of clean acetone (≤ 1 mL/L) was spiked into control medium to ensure acetone did not confound results.
Growth protocol Exposures were conducted in quadruplicated 1L glass beakers containing 750 ml of exposure water and 60 D. magna (6-8 days old) for 24 hours at 24 ± 1°C using a 16:8 photoperiod. The LAAP exposure was conducted using five replicates containing 115 D. magna each to increase statistical power. At the conclusion of each exposure, D. magna in each replicate and exposure were counted, weighed and flash-frozen then stored at -80oC until needed
Extracted molecule total RNA
Extraction protocol Total RNA was isolated using RNeasy kits (Qiagen, Valencia, CA, USA). RNA quality was assessed with an Agilent 2100 Bioanalyzer (Agilent, Wilmington, DE, USA) and quantity was determined using a Nanodrop® ND-1000 spectrophotometer (Nanodrop Technologies, Wilmington, DE, USA). Total RNA was stored at -80oC until analyzed.
Label Cy3
Label protocol cDNA synthesis, cRNA labelling, amplification and hybridization were performed following the manufacturer's kits and protocols (Quick Amp Labeling kit; Agilent, Palo Alto, CA).
 
Hybridization protocol The Agilent one-color microarray hybridization protocol (One-Color Microarray-Based Gene Expression Analysis, version 5.7, Agilent Technologies, Palo Alto, CA) was used for microarray hybridizations following the manufacturer’s protocol and recommendations.
Scan protocol An Agilent G2565CA Scanner (Agilent Technologies, Palo Alto, CA) was used to scan microarray images.
Description Gene expression after 24h exposure to control water
Data processing Microarray image processing and data pre-processing were performed Agilent's Feature Extraction software v 9.5 following the manufacturer’s protocol and recommendations.
 
Submission date Jun 22, 2011
Last update date Jun 23, 2011
Contact name Natalia Vinas
E-mail(s) natalia@icnanotox.org, nataliarv@gmail.com
Phone 6016343764
Organization name Mississippi State University
Street address 3909 Halls Ferry Rd
City Vicksburg
State/province MS
ZIP/Postal code 39180
Country USA
 
Platform ID GPL13761
Series (1)
GSE30163 Assessment of chemical mixtures and ground water effects on Daphnia magna transcriptomics

Data table header descriptions
ID_REF
VALUE Log (log10) of the processed signal

Data table
ID_REF VALUE
DM14626P1 0.18300247
DM03616P1 1.0362535
DM07320P4 -0.6760769
DM10196P1 -0.38513803
DM05301P3 0.8294873
DM05804P1 -0.057798386
DM02129P1 0.70470214
DM00526P2 1.5083296
DM11441P1 0.001299858
DM10353P2 -0.8027258
DM07508P1 1.5960598
DM14422P3 -0.21097565
DM05775P3 1.8324165
DM09445P1 -0.9167347
DM12969P1 -0.6439948
DM02268P3 1.9327395
DM09930P1 -0.38609886
DM03127P1 0.4323144
DM00209P3 -2.5935755
DM05088P1 0.9679327

Total number of rows: 14337

Table truncated, full table size 292 Kbytes.




Supplementary file Size Download File type/resource
GSM746951.txt.gz 2.1 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap