GTR Test Accession:
Help
GTR000593311.2
Last updated in GTR:
2024-05-24
View version history
GTR000593311.2,
last updated:
2024-05-24
GTR000593311.1,
registered in GTR:
2021-06-08
Last annual review date for the lab: 2024-05-28
LinkOut
At a Glance
Methods (2):
Help
Molecular Genetics - Deletion/duplication analysis: Next-Generation (NGS)/Massively parallel sequencing (MPS); ...
Target population: Help
Individuals with clinical features of glutaric acidemia type II
Clinical validity:
Help
Not provided
Clinical utility:
Help
Not provided
Ordering Information
Offered by:
Help
Test short name:
Help
GA2P
Specimen Source:
Help
- Peripheral (whole) blood
- View specimen requirements
Who can order: Help
- Genetic Counselor
- Health Care Provider
- Licensed Dentist
- Licensed Physician
- Nurse Practitioner
- Physician Assistant
- Public Health Mandate
- Registered Nurse
Lab contact:
Help
Elizabeth Selner, MS, CGC, Certified Genetic counselor, CGC, Genetic Counselor
gcmolgen@mayo.edu
800-533-1710
gcmolgen@mayo.edu
800-533-1710
Contact Policy:
Help
Laboratory can only accept contact from health care providers. Patients/families are encouraged to discuss genetic testing options with their health care provider.
How to Order:
Help
https://www.mayocliniclabs.com/test-catalog/Specimen/608029
Order URL
Order URL
Test service:
Help
Clinical Testing/Confirmation of Mutations Identified Previously
OrderCode: FMTT
OrderCode: FMTT
Test development:
Help
Test developed by laboratory (no manufacturer test name)
Informed consent required:
Help
Based on applicable state law
Pre-test genetic counseling required:
Help
No
Post-test genetic counseling required:
Help
No
Recommended fields not provided:
Test strategy
Conditions
Help
Total conditions: 4
Condition/Phenotype | Identifier |
---|
Test Targets
Genes
Help
Total genes: 8
Gene | Associated Condition | Germline or Somatic | Allele (Lab-provided) | Variant in NCBI |
---|
Methodology
Total methods: 2
Method Category
Help
Test method
Help
Instrument
Deletion/duplication analysis
Next-Generation (NGS)/Massively parallel sequencing (MPS)
Sequence analysis of the entire coding region
Next-Generation (NGS)/Massively parallel sequencing (MPS)
Illumina NovaSeq6000
Clinical Information
Test purpose:
Help
Diagnosis
Target population:
Help
Individuals with clinical features of glutaric acidemia type II
View citations (1)
- Frerman FE, Goodman SI: Defects of electron transfer flavoprotein and electron transfer flavoprotein-ubiquinone oxidoreductase: Glutaric acidemia type II. In: Valle DL, Antonarakis S, Ballabio A, Beaudet AL, Mitchell GA, eds. The Online Metabolic and Molecular Bases of Inherited Disease. McGraw-Hill; 2019. Accessed December 20, 2019. Available at www.ommbid.com
Variant Interpretation:
What is the protocol for interpreting a variation as a VUS?
Help
All detected variants are evaluated according to the most recent American College of Medical Genetics and Genomics (ACMG) and Association for Molecular Pathology (AMP) recommendations. Variants are classified based on known, predicted, or possible pathogenicity and reported with interpretive comments detailing their potential or known significance.
All detected variants are evaluated according to the most recent American College of Medical Genetics and Genomics (ACMG) and Association for Molecular Pathology (AMP) recommendations. Variants are classified based on known, predicted, or possible pathogenicity and reported with interpretive comments detailing their potential or known significance.
Are family members with defined clinical status recruited to assess significance of VUS without charge?
Help
Yes. Contact lab for details
Yes. Contact lab for details
Will the lab re-contact the ordering physician if variant interpretation changes?
Help
No. The laboratory encourages health care providers to contact the laboratory at any time to learn how the status of a particular variant may have changed over time.
No. The laboratory encourages health care providers to contact the laboratory at any time to learn how the status of a particular variant may have changed over time.
Research:
Is research allowed on the sample after clinical testing is complete?
Help
Research testing is only performed under IRB approved protocol with an opt-out policy in place.
Research testing is only performed under IRB approved protocol with an opt-out policy in place.
Recommended fields not provided:
Clinical validity,
Clinical utility,
Sample negative report,
Sample positive report
Technical Information
Test Procedure:
Help
Next-generation sequencing (NGS) and/or Sanger sequencing is performed to test for the presence of variants in coding regions and intron/exon boundaries of the genes analyzed. NGS and/or a polymerase chain reaction (PCR)-based quantitative method is performed to test for the presence of deletions and duplications in the genes analyzed
Test Confirmation:
Help
Confirmation of select reportable variants may be performed by alternate methodologies based on internal laboratory criteria. PCR-based methods and/or Sanger sequencing is used to confirm variants detected by NGS when appropriate
Availability:
Help
Tests performed
Entire test performed in-house
Entire test performed in-house
Analytical Validity:
Help
At least 99% of the bases are covered at a read depth >30X. Sensitivity is estimated at >99% for single nucleotide variants, >94% for indels up to 39 base pairs, >95% for deletions up to 75 base pairs and insertions up to 47 base pairs.
Assay limitations:
Help
Clinical Correlations: Test results should be interpreted in context of clinical findings, family history, and other laboratory data. Misinterpretation of results may occur if the information provided is inaccurate or incomplete. If testing was performed because of a clinically significant family history, it is often useful to first test an …
View more
Proficiency testing (PT):
Is proficiency testing performed for this test?
Help
Yes
Method used for proficiency testing: Help
platform PT performed
Yes
Method used for proficiency testing: Help
platform PT performed
VUS:
Software used to interpret novel variations
Help
Variants may be analyzed using any combination of the following: Alamut, REVEL, Polyphen-2, SIFT, AGVGD, MutationTaster, SpliceSiteFinder-like, MaxEntScan, NNSPLICE, GeneSplicer, SpliceAI, gene-specific online databases, ISCA, UCSC Genome Browser
Laboratory's policy on reporting novel variations Help
All novel variants and copy number variants are evaluated for potential pathogenicity and included in the written report, accordingly.
Variants may be analyzed using any combination of the following: Alamut, REVEL, Polyphen-2, SIFT, AGVGD, MutationTaster, SpliceSiteFinder-like, MaxEntScan, NNSPLICE, GeneSplicer, SpliceAI, gene-specific online databases, ISCA, UCSC Genome Browser
Laboratory's policy on reporting novel variations Help
All novel variants and copy number variants are evaluated for potential pathogenicity and included in the written report, accordingly.
Recommended fields not provided:
Citations to support assay limitations,
Description of internal test validation method,
Citations for Analytical validity,
PT Provider,
Description of PT method,
Major CAP category, CAP category, CAP test list
Regulatory Approval
FDA Review:
Help
Category:
FDA exercises enforcement discretion
Additional Information
Clinical resources:
Practice guidelines:
IMPORTANT NOTE:
NIH does not independently verify information submitted to GTR; it relies on submitters to provide information that is accurate and not misleading.
NIH makes no endorsements of tests or laboratories listed in GTR. GTR is not a substitute for medical advice.
Patients and consumers
with specific questions about a genetic test should contact a health care provider or a genetics professional.