NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM6626372 Query DataSets for GSM6626372
Status Public on Aug 17, 2023
Title Whole blood - Ag.0_Al.H_Ap.0_St.0 - Gelding - RINALDO_ROUGE
Sample type RNA
 
Source name Whole blood
Organism Equus caballus
Characteristics agressiveness: 0.0000
horse type: Gelding
animal: RINALDO_ROUGE
washbatch: 2
Extracted molecule total RNA
Extraction protocol Venous blood (10 ml) was collected from 51 horses using EDTA tubes (BD Vacutainer®). In order to stabilized intracellular RNA, 0.8 ml of venous blood was transferred in a tube containing 0.8 ml of Lysis Buffer DL (Macherey-Nagel, Düren, Germany). After homogenization, the samples were maintained at -20°C until RNA extraction. Total RNA was extracted using the NucleoSpin® RNA Blood kit (Macherey-Nagel, Düren, Germany). The manufacturer’s protocol was modified to obtained sufficient ARN quantities for the Microarray gene expression analyses: extraction was carried out from 1.6 ml of the mix blood and Lysis Buffer DL. Twenty µl of proteinase K was then added to complete blood lysis. To adjust RNA binding conditions, 0.8 ml of 70% ethanol was added. The following steps were not modified, except the elution that was carried out with 40 µl of RNase free water. Total RNA quality was assessed using RNA Pico chips on a Bioanalyser 2100 (Agilent, Boeblingen, Germany) and and its concentration was measured on a Nano Drop One Spectrophotometer (ThermoScientific, Illkirch, France).
Label Cy3
Label protocol For each sample, Cyanine-3 (Cy3) labeled cRNA was prepared from 50 ng of total RNA using the One-Color Quick Amp Labeling kit (Agilent Technologies, Santa Clara, CA) according to the manufacturer's instructions, followed by Agencourt RNAClean XP (Agencourt Bioscience Corporation, Beverly, Massachusetts) purification. Dye incorporation and cRNA yield were checked using Dropsense™ 96 UV/VIS droplet reader (Trinean, Belgium).
 
Hybridization protocol 600 ng of Cy3-labelled cRNA (specific activity >6 pmol Cy3/µg cRNA) was fragmented at 60°C for 30 minutes in a reaction volume of 25 µl containing 10x Agilent fragmentation buffer and 25x Agilent blocking agent following the manufacturer's instructions (Agilent Technologies, Santa Clara, CA). On completion of the fragmentation reaction, 25 µl of 2x Agilent hybridization buffer was added to the fragmentation mixture and hybridized to SurePrint G3 Horse_60K_2016_01_22 021322 GE 8x60K (AMID 081421) enclosed in Agilent SureHyb-enabled hybridization chambers for 17 hours at 65°C in a rotating Agilent hybridization oven. After hybridization, microarrays were washed sequentially in Wash buffer 1 (Agilent Technologies, 1 min) and Wash buffer 2 (Agilent Technologies, 37°C, 1 min).
Scan protocol Slides were scanned immediately after washing on a Agilent G2505C Microarray Scanner with Agilent Scan Control A.8.5.1 software
Data processing The scanned images were analyzed with Feature Extraction Software 10.10.1.1 (Agilent Technologies, Santa Clara, CA) using default parameters (protocol GE1_1010_Sep10 and Grid: 081421_D_F_20160126). All subsequent data analyses were done under R (www.r-project.org) using packages of Bioconductor (www.bioconductor.org). Raw data (median of pixels intensity) were imported into R using the read.maimages function from the limma package with the following weight function (assigning a weight of 1 or 0 to each spot): myfunw<-function(x) {okType<-x$ControlType==0; okFoundGreen<-x$gIsFound==1; okPos=x$gIsPosAndSignif==1; okWellAbove<- x$gIsWellAboveBG==1; as.numeric(okType & okFoundGreen & okPos & okWellAbove);} We selected the spots with a minimal weight of 1 for 6 out of 45 microarrays. At this step, 42126 spots out of 62976 were selected. The mean signal of the 16 first samples and 29 last ones were subtracted to individuals signals to correct the batch effect of the 2 serials (characteristics:WashBatch) observed during the microarray washing procedure. Data were then stored in an ExpressionSet object and normalized by the quantile method using the normalize.quantiles function from the preprocessCore R library. Replicated probes on the array (identical ProbeName) were resolved by taking the median normalized signal of each set of replicated probes. The resulting matrix has 30265 rows each corresponding to a unique ProbeName (provided as data Matrix).
 
Submission date Oct 11, 2022
Last update date Aug 17, 2023
Contact name Aline FOURY
E-mail(s) aline.foury@inrae.fr
Organization name INRAE
Lab NutriNeuro
Street address 146 rue Léo Saignat
City Bordeaux
ZIP/Postal code 33600
Country France
 
Platform ID GPL32737
Series (1)
GSE215200 Transcriptomic signature related to welfare of horses housed in individual boxes

Data table header descriptions
ID_REF
VALUE log2 normalized signal

Data table
ID_REF VALUE
A_69_P021840 7.237170148
A_69_P038701 6.509057644
A_69_P042611 4.989021691
A_69_P081456 10.47752192
A_69_P102727 5.119679438
A_69_P076476 10.9686641
A_69_P056736 6.783773873
A_69_P035026 5.771606683
A_69_P043221 7.385895055
A_69_P078173 11.68862129
A_69_P011951 7.280443708
A_69_P081826 7.837650599
A_69_P044003 7.23885361
A_69_P040971 5.375960917
A_69_P052958 11.67235766
A_69_P044161 5.97199403
A_69_P019186 9.331795234
A_69_P019602 5.904688976
A_69_P052487 5.526431441
A_69_P065568 8.677071764

Total number of rows: 30265

Table truncated, full table size 734 Kbytes.




Supplementary file Size Download File type/resource
GSM6626372_US10463851_258142110028_S01_GE1_1010_Sep10_2_3.txt.gz 11.8 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap