NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM706161 Query DataSets for GSM706161
Status Public on May 02, 2011
Title seq-NA_N2_L3_1_mE1 [input DNA]
Sample type SRA
 
Source name Control sample from L3 stage N2 worms, whole body
Organism Caenorhabditis elegans
Characteristics tissue: whole body
strain: N2
Stage: L3
Treatment protocol Worm_L3_extraction_vPK1. Worms are frozen, ground, and crosslinked for 10 minutes in 1% formaldehyde. Later, washed pellets are resuspended in FA buffer and subjected to sonication in Bioruptor (14 pulses of 30 seconds with 1 minute rests in between). Extracts are then spun down and soluble fraction is stored for quality tests and future ChIP.
Growth protocol Worm_L3_growth_and_harvest_vPK1. About 2-7 million of worms are bleached and then hatched in M9 for 24-42 hrs. About 100 embryos are seeded onto the plate to test for contamination and hatching efficiency. Remaining hatched L1 larvae are inoculated in a proper volume of liquid culture. Next day when larvae reach the L3 stage they are cleaned by M9 washes and sucrose gradient and collected by freezing in liquid nitrogen. Just before collection DIC pictures are taken and about 50ul of worms are stained for DAPI to assess the stage.
Extracted molecule genomic DNA
Extraction protocol Libraries were prepared according to Illumina's instructions for "Preparing Samples for ChIP Sequencing of DNA", with some variation. DNA was end-repaired using T4 DNA polymerase, Klenow DNA polymerase and T4 DNA polymerase. A's were then added to the 3' ends of the fragments using Kelow fragment (3' 5' exo minus). Paired-end adapters were then ligated onto the ends of the fragments. DNA library was size selected by gel purification, fragments of 250-500 bp were band isolated from an agarose gel. DNA was PCR amplified for 18 cycles. The Bioanalyzer was used to verify fragment purification and quantify DNA.
 
Library strategy ChIP-Seq
Library source genomic
Library selection ChIP
Instrument model Illumina Genome Analyzer II
 
Description C. elegans N2 L3 input control.

Input lanes for ChIP-seq analysis of elements that specify nucleosome positioning and occupancy, control domains of gene expression, induce repression of the X chromosome, guide mitotic segregation and genome duplication, govern homolog pairing and recombination during meiosis, and organize chromosome positioning within the nucleus.

Contributors: Julie Ahringer, Isabel Latorre.

Data processing BWA is a fast light-weighted tool that aligns relatively short sequences to a sequence database. The algorithms is based on Burrows-Wheeler Transform (BWT). See the link @ http://bio-bwa.sourceforge.net/. It runs as DEFAULT for both bwa aln and bwa samse.
Processed data file build: ce6
 
Submission date Apr 09, 2011
Last update date May 15, 2019
Contact name Tristan De Buysscher
Organization name University of North Carolina at Chapel Hill
Department Biology
Lab Lieb
Street address CB# 3280, Coker Hall
City Chapel Hill
State/province NC
ZIP/Postal code 27599-3280
Country USA
 
Platform ID GPL9269
Series (10)
GSE28756 seq-AB1791_H3_N2_L3
GSE28757 seq-AR0144_H3_144_N2_L3
GSE28758 seq-BH00001_LIN52_N2_L3
Relations
SRA SRX059220
BioSample SAMN00261238
Named Annotation GSM706161_seq-NA_N2_L3_1_mE1_macs14_MACS_wiggle_cat.wig.gz

Supplementary file Size Download File type/resource
GSM706161_seq-NA_N2_L3_1_mE1_macs14_MACS_wiggle_cat.wig.gz 28.4 Mb (ftp)(http) WIG
SRA Run SelectorHelp
Raw data are available in SRA
Processed data provided as supplementary file

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap