NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM770028 Query DataSets for GSM770028
Status Public on Oct 01, 2011
Title D. montana whole body 1-hour recovery from chill coma rep3
Sample type RNA
 
Source name Whole body pool of then flies 1hourrecovery rep6
Organism Drosophila montana
Characteristics gender: female
developmental stage: mature
age: 20 d
treatment: Whole body 1-hour recovery from chill coma
Extracted molecule total RNA
Extraction protocol Three pools of ten flies per sample were grounded and transferred into 1.5 ml tubes and mixed with 600 µl of lysis buffer. The total RNA was extracted using Qiagen RNA extraction kit with RNase-Free DNase treatment according to manufacturer's protocols (QIAGEN, Hilden, Germany). The purity of each RNA sample was measured with NanoDrop ND-1000 spectrophotometer (NanoDrop Technologies, Wilmington, DE, USA) and the integrity of the samples was studied with Agilent’s Bioanalyzer (Agilent, Santa Clara, CA, USA).
Label Cy3
Label protocol 600 ng of total RNA from each replicate was amplified and Cy3-labeled with Agilent’s Quick Amp Labeling (One Color) Kit and processed together with Agilent’s One-Colour RNA Spike-in Kit.
 
Hybridization protocol 600 ng of each cRNA sample was hybridized to Agilent’s 8x15K D. montana / D. virilis custom arrays at 65˚C. Hybridization was performed overnight using Agilent’s Gene Expression Hybridization Kit and the plates were washed with Agilent’s Gene Expression Wash Pack and Stabilization and Drying solution.
Scan protocol Arrays were scanned with Agilent Technologies Scanner (model G2565CA) and numerical results were extracted with Feature Extraction software version 10.7.1 using 026691_D_F_20091221grid, GE1_107_Sep09 protocol and GE1_QCMT_Sep09 metric set.
Data processing The downstream analysis of the microarray data was carried out using R (R Foundation for Statistical Computing) and Bioconductor software (Gentleman et al., 2004). Probe level quantile normalization method was used for between sample normalization, after which the signals were summarized for each probe type by taking a median value. The data was found to be of high quality and the Pearson's correlations between the samples were between 0.86 and 0.99 in the different sample groups indicating high reproducibility. The statistical analyses were carried out using Bioconductor's Limma package. For filtering out differentially expressed genes, the minimum fold change limit was set at 2 and false discovery rate (FDR) adjusted significance level at 0.05.
 
Submission date Aug 01, 2011
Last update date Oct 01, 2011
Contact name Laura Vesala
E-mail(s) laura.vesala@jyu.fi
Organization name University of Jyväskylä
Department Department of Biological and Environmental Science
Street address Survontie 9
City Jyväskylä
ZIP/Postal code 40100
Country Finland
 
Platform ID GPL14008
Series (1)
GSE31103 Changes in gene expression during cold exposure in Drosophila montana and D. virilis

Data table header descriptions
ID_REF
VALUE Normalized signal intensity

Data table
ID_REF VALUE
1 3220.976140625
2 2793.53266666667
3 199.447796875
4 35.4914773958333
5 2780.3301875
6 34.0566134375
7 298.502392708333
8 6.16821553125
9 16.659034828125
10 1.99655509375
11 3.4692215
12 73.2664140104167
13 2664.33913020833
14 307.604895833333
15 1027.29165677083
16 21.0617090625
17 125.7304975
18 60.16051921875
19 3.46580865625
20 2.21466046354167

Total number of rows: 1850

Table truncated, full table size 36 Kbytes.




Supplementary file Size Download File type/resource
GSM770028_M_REC2_s3.txt.gz 762.2 Kb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap